Why is emission wavelength longer than excitation




















In order to determine the emission spectrum of a particular fluorochrome, the wavelength of maximum absorption usually the same as the excitation maximum is determined and the fluorochrome is excited at that wavelength. The absorption spectrum of a typical fluorochrome is illustrated in Figure 1 a where the relative intensity of absorption is plotted against the measured wavelength. A monochromator a device that allows narrow bands of light wavelengths to pass is then used to scan the fluorescence emission intensity over the entire series of emission wavelengths.

The relative intensity of the fluorescence is measured at the various wavelengths to plot the emission spectrum, as illustrated in Figure 1 b. The excitation spectrum of a given fluorochrome is determined in a similar manner by monitoring fluorescence emission at the wavelength of maximum intensity while the fluorophore is excited through a group consecutive wavelengths.

The emission maximum is chosen and only emission light at that wavelength is allowed to pass to the detector. Excitation is induced usually by means of a monochromator at various excitation wavelengths and the intensity of the emitted fluorescence is measured as a function of wavelength. The result is a graph or curve illustrated in Figure 1 a , which depicts the relative fluorescence intensity produced by excitation over the spectrum of excitation wavelengths.

Explore the overlap regions of fluorescence excitation, emission, and dichromatic filter spectral profiles and how changes in the transmission characteristics determine the bandwidth of wavelengths passed through various filter combinations. Several observations can be made from a typical excitation and emission set of curves or spectra. There is usually an overlap between the higher wavelength end of the excitation spectrum and the lower wavelength end of the emission spectrum. This overlap of excitation and emission intensities and wavelengths illustrated in Figure 1 c must be eliminated, in fluorescence microscopy, by means of the appropriate selection for an excitation filter, dichromatic beamsplitter in reflected light fluorescence , and barrier or emission filter.

Otherwise, the much brighter excitation light overwhelms the weaker emitted fluorescence light and significantly diminishes specimen contrast. When electrons go from the excited state to the ground state see the section below entitled Molecular Explanation , there is a loss of vibrational energy. As a result, the emission spectrum is shifted to longer wavelengths than the excitation spectrum wavelength varies inversely to radiation energy.

This phenomenon is known as Stokes Law or Stokes shift. The greater the Stokes shift, the easier it is to separate excitation light from emission light. The emission intensity peak is usually lower than the excitation peak, and the emission curve is often a mirror image of the excitation curve, but shifted to longer wavelengths. In order to achieve maximum fluorescence intensity, the fluorochrome is usually excited at the wavelength at the peak of the excitation curve, and the emission detection is selected at the peak wavelength or other wavelengths chosen by the observer of the emission curve.

The selections of excitation wavelengths and emission wavelengths are controlled by appropriate filters. In determining the spectral response of an optical system, technical corrections are required to take into account such factors as glass transmission and detector sensitivity variables for different wavelengths. A typical fluorochrome absorption-emission spectral diagram is illustrated in Figure 2. Note that the curves of fluorescence intensity for absorption usually similar to the excitation curve for pure compounds and emission for this typical fluorochrome are somewhat similar in shape.

The wavelength shift between excitation and emission has been known since the middle of the nineteenth century Stokes Law. Also note that the excitation and emission curves overlap somewhat at the upper end of the excitation and the lower wavelengths of the emission curve. Discover how variations in the bandpass wavelength region of excitation and barrier filters allow a specific band of wavelengths to illuminate the specimen, and then pass through to the detector while all others are excluded.

The separation of excitation and emission wavelengths is achieved by the proper selection of filters to block or pass specific wavelengths of the spectrum as presented in Figure 3. The design of fluorescence illuminators is based on control of excitation light and emission light by readily changeable filter insertions into the light path on the way toward the specimen and then emanating from the specimen.

Some cell lines label well, others partially, others not at all. So I always recommend at least a light permeabilization to insure good labeling. Incubate for 1—5 minutes.

Rinse the sample several times in PBS. The main difference is that the DAPI is more toxic so if you stain live cells they will not be alive for long. Unfortunately both require UV or near UV excitation so in any case they are not the best choice if you would like to image them in living cells.

DAPI staining was used to determine the number of nuclei and to assess gross cell morphology. DAPI staining allows multiple use of cells eliminating the need for duplicate samples. Incubate for 1—5 minutes, protected from light…. Labeling fixed cells. Two types of fluorescent dyes have been commonly used for immunofluorescence microscopy, i.

Dyes that bind to DNA, such as Hoechst , are commonly used to visualize chromatin in live cells by fluorescence microscopy. A caveat is that the probes themselves should not perturb cellular responses and under normal conditions the dyes are generally non-toxic.

Begin typing your search term above and press enter to search. This action takes a little longer about a microsecond or two than usual fluorescence and is called delayed fluorescence Figure 4 c. Under other circumstances for example, photobleaching or the presence of salts of heavy metals or other chemicals , emitted light may be significantly reduced or halted altogether, as discussed below.

There are specific conditions that may affect the re-radiation of light by an excited fluorophore, and thus reduce the intensity of fluorescence. This reduction of emission intensity is generally called fading or photobleaching. Some authors further subdivide fading into quenching and bleaching. Bleaching is irreversible decomposition of the fluorescent molecules because of light intensity in the presence of molecular oxygen.

Quenching also results in reduced fluorescence intensity and frequently is brought about as a result of oxidizing agents or the presence of salts of heavy metals or halogen compounds. Often, quenching results from the transfer of energy to other acceptor molecules physically close to the excited fluorophores, a phenomenon known as resonance energy transfer.

This particular phenomenon has become the basis for a newer technique of measuring distances far below the lateral resolution of the light microscope. The occurrence of bleaching has led to a technique known as FRAP , or fluorescence recovery after photobleaching. FRAP is based upon bleaching by short laser bursts and subsequent observation of the recovery of fluorescence caused by the diffusion of fluorophores into the bleached area.

To reduce the degree of fading in some specimens, it may be advisable to use a neutral density filter in the light path before the illumination reaches the excitation filter, thus diminishing the excitation light intensity. In other instances, fading effects may be reduced by changing the pH of the mounting medium or by using anti-bleaching agents several of the more important agents are listed in Table 2. For digital imaging, photomicrography, or simply visual observation, rapidly changing the field of view may also avoid fading effects.

Mortimer Abramowitz - Olympus America, Inc. Michael W. Microscopy Primer. Light and Color. Microscope Basics. Special Techniques. Digital Imaging. Confocal Microscopy. Live-Cell Imaging. Microscopy Museum. Virtual Microscopy. Web Resources. License Info.